Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
1.
Braz. dent. sci ; 27(1): 1-7, 2024. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1532450

RESUMO

Objective: The aim of this study was to determine if SEM used with imaging software could be used to quantitatively determine the extent of dentine roughness due to tooth-brushing. Material and methods: Flat, polished dentine surfaces were subjected to 25,000 cycles of simulated tooth-brushing at 2 strokes per second with a load of 200 g. At the end of the brushing cycle, dentine surfaces were first assessed using profilometry and then subjected to SEM analysis. Ra (average roughness) readings were obtained for profilometric assessment. Using imaging software, the horizontal distance between adjacent characteristic grooves noted on micrographs was measured, ensuring that the middle of each crest of the associated groove was used as the reference point, the Crest-to-Crest distance (C-C distance). These two parameters were examined statistically for correlation. Results: When Spearman Rank tests were utilized the correlation between average Ra and crest to crest measurements was 0.709 (p <0.01). The Bland Altman plot, however, showed poor agreement between the two test parameters. Conclusion: Further work is needed to validate the use of this methodology in the quantitative assessment of tooth surface loss due to abrasion (AU)


Objetivo: O objetivo deste estudo foi determinar se o MEV usado com software de imagem poderia ser usado para determinar quantitativamente a extensão da rugosidade da dentina devido à escovação dentária. Material e Métodos: Superfícies dentinárias planas e polidas foram submetidas a 25.000 ciclos de escovação dentária simulada a 2 movimentos por segundo com uma carga de 200g. No final do ciclo de escovação, as superfícies dentinárias foram primeiro avaliadas por perfilometria e depois submetidas à análise MEV. Leituras de Ra (rugosidade média) foram obtidas para avaliação perfilométrica. Utilizando um software de imagem, foi medida a distância horizontal entre sulcos característicos adjacentes observados nas micrografias, garantindo que o meio de cada crista do sulco associado fosse usado como ponto de referência, a distância crista a crista (distância CC). Esses dois parâmetros foram examinados estatisticamente para correlação. Resultados: Quando foram utilizados os testes de Spearman Rank, a correlação entre a média de Ra e as medidas de crista a crista foi de 0,709 (p<0,01). O gráfico de Bland Altman, no entanto, mostrou fraca concordância entre os dois parâmetros de teste. Conclusão: Mais trabalhos são necessários para validar o uso desta metodologia na avaliação quantitativa da perda da superfície dentária devido à abrasão(AU)


Assuntos
Propriedades de Superfície , Abrasão Dentária , Escovação Dentária , Microscopia Eletrônica de Varredura , Dentina
2.
Rev. Fac. Odontol. Porto Alegre ; 64(1): e130840, dez 2023.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1526324

RESUMO

Objetivo: Avaliar o efeito de dois métodos de profilaxia sobre a rugosidade superficial de diferentes resinas compostas. Materiais e Métodos: Dez amostras (7 mm x 2 mm) foram confeccionadas para cada resina testada: MH - resina microhíbrida (viscosidade regular - Opallis); NH ­ resina nanohíbrida (viscosidade regular - Vittra APS); BF ­ resina bulk fill (alta viscosidade - Opus Bulk Fill); MHF ­ resina fluida microhíbrida (Opallis flow); e OS ­ resina nanohíbrida camaleão (viscosidade regular - Vittra Unique). Os valores iniciais de rugosidade (Rai) foram obtidos para cada amostra e então subdivididas em dois grupos (n = 5) seguindo o método de profilaxia: SB ­ jato de bicarbonato de sódio (125µm, 30 s, 10 mm de distância, 2 bar); e PP ­ profilaxia com pasta de pedra-pomes e escova rotatória (30 s, 3000 rpm e pressão de 150 g). Após, uma nova medida de Ra (Raf) foi obtida, e a diferença calculada (ΔRa). Os dados foram analisados pelo teste ANOVA três fatores e teste de Bonferroni, e a diferença de rugosidade (ΔRa) pelo teste Anova dois fatores e teste de Tukey (p<0,05). Resultados: MHF apresentou maior rugosidade após profilaxia com jato de bicarbonato, enquanto para NH a abrasão com pedra pomes foi mais deletéria. Para os demais grupos não houve diferença. Discussão: A alteração na rugosidade promovida pela profilaxia é material-dependente. Conclusão: A profilaxia profissional com jato de bicarbonato ou abrasão com pedra-pomes induziu alterações na rugosidade das resinas.


Aim: This study evaluated the effect of two prophylaxis methods over the surface roughness of different resin composites. Materials and Methods: Ten disc-shaped specimens (7 mm x 2 mm) were made for each composite tested: MH - microhybrid composite with regular viscosity (Opallis); NH ­ nanohybrid composite with regular viscosity (Vittra APS); BF ­ high-viscosity bulk fill composite (Opus Bulk Fill); MHF - microhybrid flowable composite (Opallis flow); and OS ­ nanohybrid one-shade composite with regular viscosity (Vittra Unique). Initial roughness (Ra) values were obtained from each sample, and then they were divided into two groups (n = 5) following the prophylaxis method: SB ­ prophylaxis with sodium bicarbonate powder (125µm grain) using an air-powder polishing device (30 s application distanced 10 mm with 2 bar); and PP ­ prophylaxis with pumice paste and rotatory brush (30 s, 3000 rpm and pressure of 150 g). After that, a new Ra measurement (Raf) was obtained, and the difference was calculated (ΔRa). Data were compared using Three-way ANOVA followed by Bonferroni teste and the Ra difference (ΔRa) was analyzed by Two-way ANOVA followed by the Tukey test (p<0.05). Results: MHF presented higher Ra values after receiving prophylaxis with SB, while for NH, the abrasion with pumice increased the Ra, and for the other groups, no differences were found. Discussion: Alteration promoted by prophylaxis is material dependent. Conclusion: Professional prophylaxis with a bicarbonate jet or abrasion with pumice-based paste can induce changes in the composites' roughness.

3.
Rev. Fac. Odontol. Porto Alegre ; 64(1): e130840, dez 2023.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1526407

RESUMO

Objetivo: Avaliar o efeito de dois métodos de profilaxia sobre a rugosidade superficial de diferentes resinas compostas. Materiais e Métodos: Dez amostras (7 mm x 2 mm) foram confeccionadas para cada resina testada: MH - resina microhíbrida (viscosidade regular - Opallis); NH ­ resina nanohíbrida (viscosidade regular - Vittra APS); BF ­ resina bulk fill (alta viscosidade - Opus Bulk Fill); MHF ­ resina fluida microhíbrida (Opallis flow); e OS ­ resina nanohíbrida camaleão (viscosidade regular - Vittra Unique). Os valores iniciais de rugosidade (Rai) foram obtidos para cada amostra e então subdivididas em dois grupos (n = 5) seguindo o método de profilaxia: SB ­ jato de bicarbonato de sódio (125µm, 30 s, 10 mm de distância, 2 bar); e PP ­ profilaxia com pasta de pedra-pomes e escova rotatória (30 s, 3000 rpm e pressão de 150 g). Após, uma nova medida de Ra (Raf) foi obtida, e a diferença calculada (ΔRa). Os dados foram analisados pelo teste ANOVA três fatores e teste de Bonferroni, e a diferença de rugosidade (ΔRa) pelo teste Anova dois fatores e teste de Tukey (p<0,05). Resultados: MHF apresentou maior rugosidade após profilaxia com jato de bicarbonato, enquanto para NH a abrasão com pedra pomes foi mais deletéria. Para os demais grupos não houve diferença. Discussão: A alteração na rugosidade promovida pela profilaxia é material-dependente. Conclusão: A profilaxia profissional com jato de bicarbonato ou abrasão com pedra-pomes induziu alterações na rugosidade das resinas.


Aim: This study evaluated the effect of two prophylaxis methods over the surface roughness of different resin composites. Materials and Methods: Ten disc-shaped specimens (7 mm x 2 mm) were made for each composite tested: MH - microhybrid composite with regular viscosity (Opallis); NH ­ nanohybrid composite with regular viscosity (Vittra APS); BF ­ high-viscosity bulk fill composite (Opus Bulk Fill); MHF - microhybrid flowable composite (Opallis flow); and OS ­ nanohybrid one-shade composite with regular viscosity (Vittra Unique). Initial roughness (Ra) values were obtained from each sample, and then they were divided into two groups (n = 5) following the prophylaxis method: SB ­ prophylaxis with sodium bicarbonate powder (125µm grain) using an air-powder polishing device (30 s application distanced 10 mm with 2 bar); and PP ­ prophylaxis with pumice paste and rotatory brush (30 s, 3000 rpm and pressure of 150 g). After that, a new Ra measurement (Raf) was obtained, and the difference was calculated (ΔRa). Data were compared using Three-way ANOVA followed by Bonferroni teste and the Ra difference (ΔRa) was analyzed by Two-way ANOVA followed by the Tukey test (p<0.05). Results: MHF presented higher Ra values after receiving prophylaxis with SB, while for NH, the abrasion with pumice increased the Ra, and for the other groups, no differences were found. Discussion: Alteration promoted by prophylaxis is material dependent. Conclusion: Professional prophylaxis with a bicarbonate jet or abrasion with pumice-based paste can induce changes in the composites' roughness.

4.
Acta odontol. latinoam ; 36(1): 58-65, Apr. 2023. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1447077

RESUMO

ABSTRACT Color stability is among the most frequent causes of restoration failures, and influences surface properties. Aim: The aim of this study was to investigate the influence of pigment solutions on low-shrinkage and conventional composites regarding changes in the physical properties of composite surfaces. Materials and Method: Specimens of four composites (Filtek Z350 XT, Point 4, N'Durance and Venus Diamond) were randomly distributed into three groups to be submitted to each of three pigment solutions (red wine, tomato sauce and coffee) in fifteen-minute daily cycles, for twenty-eight days. There were 12 groups altogether (n = 10). Color, surface roughness and hardness tests were performed. Statistical analysis includedAnalysis of variance (ANOVA) and Tukey's significance test (a = 0.05). Results: Color changes caused by the solutions did not differ significantly among Filtek Z350 XT, Venus Diamond and N'Durance. Hardness decreased significantly in Filtek Z350 XT and Venus Diamond after chemical challenge with each solution. For the composite independent factor, roughness was highest in Venus Diamond, followed by Filtek Z350 XT, Point 4 and N'Durance. Conclusions: Treatment with different pigment solutions (red wine, tomato sauce or coffee) increased stainability and decreased hardness of both low-shrinkage and conventional composites, while roughness was unaffected.


RESUMO A estabilidade de cor está entre as causas mais frequentes de falhas de restauragoes, que também influenciam suas propriedades superficiais. Objetivo: O objetivo do presente estudo foi investigar a influencia de solugoes de pigmentos em compósitos convencionais e de baixa retragao, bem como alteragoes naspropriedades físicas da superficie dos compósitos. Materiais eMétodo: Amostras de cada compósito (Filtek Z350XT, Point 4, N'Durance e Venus Diamond) foram distribuidas aleatoriamente em grupos submetidos a cada solugao pigmentante (vinho tinto, molho de tomate e café) em ciclos diários de quinze minutos, durante vinte e oito dias. Assim, totalizando 12 grupos (n = 10). Foram realizados testes de cor, rugosidade superficial e dureza. A Análise Estatistica foi realizada usando Análise de variáncia (ANOVA) e o teste de significáncia de Tukey (a = 0.05). Resultados: As alteragoes de cor desencadeadas pelas solugoes investigadas nao mostraram diferenga estatisticamente significativa entre os compósitos Filtek Z350 XT, Venus Diamond e N'Durance. Os valores de dureza registrados para Filtek Z350XT e Venus Diamond diminuiram significativamente após o desafio químico com cada uma das solugoes pigmentantes. Para o fator independente compósito, Venus Diamond registrou a maior rugosidade; foi seguido por Filtek Z350XT, Point 4 e N'Durance. Conclusoes: Os tratamentos das amostras com diferentes solugoes pigmentantes (vinho tinto, molho de tomate e café) aumentaram a manchabilidade dos compósitos convencionais e de baixa retragao e diminuiram sua dureza, embora nao tenham afetado a rugosidade dos compósitos.

5.
Rev. odontol. UNESP (Online) ; 52: e20230021, 2023. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1530303

RESUMO

Introdução: A importância da rugosidade para a osseointegração se dá pela correlação das interações das proteínas com a superfície do implante, a adsorção. Diferentes métodos são utilizados nos tratamentos de superfície, em que ocorre a remoção de partes da camada superficial, como o ataque ácido. Objetivo: Analisar as alterações de rugosidade na superfície dos implantes osseointegrados tratadas por duplo ataque ácido com uso único e até quatro reutilizações dos ácidos. Material e método As amostras de implantes dentários de liga de titânio (SINGULAR Implants ®) (n = 10) foram subdividas em cinco grupos: controle, tratamento 1, 2, 3 e 4, conforme as reutilizações dos ácidos. As capturas dos implantes no aumento de 500x, 1000x, 2000x e 4000x foram realizadas no microscópio eletrônico de varredura, para posterior análise de rugosidade pelo software ImageJ. Os valores de Ra e Rq foram analisados estatisticamente pelo teste ANOVA e o pós-teste de Tukey. Resultado: Os dados obtidos pelas imagens capturadas e pelos números de Ra e Rq adquiridos pelo ImageJ demonstraram que o tratamento com o duplo ataque ácido com cinco utilizações dos mesmos ácidos foi positivo para o tratamento de superfície do implante de liga de titânio. Conclusão: Pode-se concluir que até quatro reutilizações dos ácidos não interferiu estatisticamente nos valores de rugosidade em diferentes aumentos. São necessários mais estudos referentes à reutilização dos ácidos, contribuindo para a diminuição dos custos aos fabricantes, aumentando a sustentabilidade e mantendo-se a qualidade do produto.


Introduction: The importance of roughness for osseointegration is due to the configuration of proteins with the surface of the implant, and adsorption. Different methods are used in surface treatments, in which parts of the surface layer are removed, such as acid attack. Objective: To analyze changes in roughness on the surface of osseointegrated implants treated by double acid etching with single-use and up to 4 reuses of serums at a magnification of 500x, 1000x, 2000x, and 4000x in the scanning microscope (SEM). Method Samples of adherent implants (SINGULAR Implants ®) of lever alloy (n=10) were subdivided into 5 groups: control, treatment 1, 2, 3, and 4, according to the reuses. For the surface topography of the samples, SEM was used, followed by analysis by ImageJ software. Using the ANOVA test and Turkeys post-test, Ra and Rq values were statistically analyzed. Result: The data obtained both by the images captured in the SEM and by the Ra and Rq numbers acquired by the ImageJ illustrate that the treatment with the double acid attack with 5 uses of the same ones served, was positive for the surface treatment of the alloy implant of independent. Conclusion: It can be concluded that up to four reuses of food do not statistically interfere with roughness values. More studies are needed regarding the reuse of acids, certainly to reduce costs to manufacturers, increasing sustainability while maintaining product quality.


Assuntos
Propriedades de Superfície , Titânio , Implantes Dentários , Análise de Variância , Osseointegração , Adsorção , Microscopia Eletrônica de Varredura
6.
Araçatuba; s.n; 2023. 44 p. ilus, tab, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1510490

RESUMO

Atualmente novos princípios ativos de função reabsortiva têm ganhado campo de estudo para avaliar seus mecanismos e comportamento biológico. Com isso, um novo antirreabsortivo, inibidor da catepsina K tem apresentado efeito positivo na osseointegração. Este estudo tem como objetivo avaliar a resposta óssea da superfície de implantes revestida por duplo ataque ácido e Odanacatib (MK-0822) em ratas ovariectomizadas. Neste estudo foram utilizadas ratas (Albinus, Wistar) ovariectomizadas ou sham (placebo). Cinquenta e dois (52) tiveram as superfícies revestidas por duplo ataque ácido e MK-0822 a 0,06 mg/ml através do método biomimético, e 48 implantes foram instalados em tíbias de ratas ovariectomizadas ou sham. Microscopia eletrônica de varredura (MEV) e energia dispersiva de raios-x (EDS) foram realizadas em 4 implantes após tratamento de superfície, para análise da topografia e composição química, além da realização da análise do ângulo de contato em 16 discos de titânio comercialmente puro tratados com as mesmas superfícies. Aos 15 e 40 dias após instalação de implantes (n=6), foi realizada microtomografia computadorizada. Dados quantitativos foram avaliados adotando-se o nível de significância p< 0,05. Além dos resultados topográficos favoráveis para os grupos tratados com MK-0822, os resultados microtomográficos apresentaram diferença estatisticamente significante entre os grupos SHAM e OVX na maioria dos parâmetros (p< 0,05). Ainda assim, os grupos tratados com MK-0822 apresentaram resultado semelhante ou maior, porém sem diferença estatística, em relação ao grupo controle em todos os parâmetros (TV, BV, BV ̸TV, Tb.Sp e Tb.N)(AU)


Currently new active principles of resorptive function have gained field of study to evaluate their mechanisms and biological behavior. Thereby a new anti-absorbent, cathepsin K inhibitor has had a positive effect on osseointegration. This study aims to evaluate the bone response of the surface of implants coated by double acid-etched and Odanacatib (MK-0822) in ovariectomized rats. In this study, either ovariectomized rats (Albinus, Wistar) or sham (placebo) have been used. Fifty-two (52) implants had the surfaces coated with double acid-etched and MK-0822 at 0,06 mg/ml by the biomimetic method and 48 implants were installed on sham or ovariectomized rat tibias. Scanning electron microscopy (SEM) and X-ray dispersive energy (EDS) were performed in 4 implants after surface treatment for analysis of topography and chemical composition, in addition to performing contact angle analysis on 16 commercially pure titanium discs treated with the same surfaces. At 15 and 40 days after implant installation, microcomputer tomography was performed. Quantitative data was evaluated by adopting the significance level of p< 0.05. Besides the favorable topographic results to MK-0822 coated implants group, the microtomographic results presents statistically significant differences between the SHAM and OVX groups at most of the parameters (p< 0,05). Nevertheless, the MK-0822 coated group presents similar or higher values, although without statistic differences related to the control group in all parameters (TV, BV, BV ̸TV, Tb.Sp and Tb.N)(AU)


Assuntos
Animais , Ratos , Propriedades de Superfície , Reabsorção Óssea , Implantes Dentários , Ratos Wistar , Catepsina K
7.
Natal; s.n; 2023. 38 p. tab, ilus.
Tese em Português | BBO - Odontologia | ID: biblio-1437715

RESUMO

Introdução: O aumento da exigência estética pelos pacientes e o contínuo desenvolvimento de materiais - tais como resinas bulk fill de alta e baixa viscosidade e flow, demanda uma crescente necessidade de estudos nesta área para avaliar as propriedades dos materiais quando submetidos ao desgaste ocasionado pela escovação dentária ao longo do tempo. Objetivo: Avaliar as características superficiais de restaurações antes e após o processo de escovação simulada e comparar os resultados entre os mesmos. Materiais e métodos: Foram confeccionados ao total 80 corpos de prova (7x4mm), sendo 20 para cada tipo de resina utilizada, na cor A1: Bulk Fill One (3M/ESPE, St. Paul, MN, USA), Bulk Fill Flow (3M/ESPE, St. Paul, MN, USA), Z350XT (3M/ESPE St. Paul, MN, USA) e Z350XT Flow (3M/ESPE, St. Paul, MN, USA). Após a confecção, os corpos de prova permaneceram por 24 horas imersos em água destilada em estufa a 37°C, momento no qual foi realizado o acabamento e polimento com a sequência de discos de lixa Praxis (TDV, Brasil). Metade dos corpos de prova foi submetida a 60,000 ciclos de escovação simulada, enquanto a outra metade foi o grupo controle (n=10). A superfície das restaurações foi avaliada por meio do Microscópio Eletrônico de Varredura (MEV), rugosidade superficial (Ra) e variação de massa (através de pesagem) das restaurações antes e após o processo de escovação simulada. Para análise estatística, foi utilizada a análise de variância ANOVA dois fatores e pós teste de Tukey. Resultados: Na análise feita pelo MEV, em amplificação de 500x, foi observada a protuberância de partículas médias e pequenas em todas as resinas após a escovação simulada, com exceção da resina de tipo Z350 flow. Todos os materiais apresentaram aumento da Ra após a escovação simulada. Com relação a variação de massa, não houve diferença estatisticamente significativa. Conclusão: O processo abrasivo ocasionado pela escovação leva a mudanças na disposição das partículas, o que ocasiona mudanças na superfície do material e aumento na rugosidade. Por outro lado, não foi demonstrada diferença com relação a variação de massa (AU).


Introduction: The increasing of the aesthetic exigency by the patients and the continual development of materials ­ such as bulk fill and flow composites, demands a crescent need of studies on this area to evaluate the properties of the materials when submitted to the wear occasioned by toothbrushing abrasion over time. Objective: To evaluate the surface characteristics of restorations performed before and after the process of simulated toothbrushing and to compare the results between the composites. Materials and methods: In total, 80 samples were made (7x4mm), being 20 to each type of resin utilized, color A1: Bulk Fill One (3M/ESPE, St. Paul, MN, USA), Bulk Fill Flow (3M/ESPE, St. Paul, MN, USA), Z350XT (3M/ESPE St. Paul, MN, USA) and Z350XT Flow (3M/ESPE, St. Paul, MN, USA). After the confection of the specimens, the samples were immersed in distilled water for 24 hours and stored at 37°C in stove, moment that was performed the finishing and polishing with the sequence of sandpaper discs (TDV, Brasil). Half of the specimens was submitted to 60,000 cycles of simulated toothbrushing, meanwhile the other half was the control group (n=10). The surface of the restorations was evaluated through Scanning Electronic Microscopy (SEM), surface roughness (Ra), and weight loss (through measurements), in two moments: before and after the process of simulated toothbrushing. To the statistical analysis, it was used the variance analysis ANOVA two factors and Tukey's post test. Results: In the analysis performed by SEM, in amplification of 500x, it was observed the presence of medium and small protruding particles in all resins tested after simulated toothbrushing, with exception of the resin Z350 flow. All materials presented increasing on Ra after simulated toothbrushing. Regarding to mass variation, there was not any significant statistical difference. Conclusion: The abrasive process occasioned by toothbrushing leads to changes on the particles disposition, which causes changes on the surface and increase on the roughness. On the other hand, there was not any difference regarding to mass variation (AU).


Assuntos
Propriedades de Superfície , Microscopia Eletrônica de Varredura/instrumentação , Resinas Compostas/química , Desgaste dos Dentes , Análise de Variância
8.
Rev. Fac. Odontol. Porto Alegre (Online) ; 62(1): 44-55, jan.-jun. 2021.
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1443417

RESUMO

Introdução: O objetivo deste trabalho foi avaliar a influência de diferentes métodos de tratamento de superfície em pinos de fibra de vidro com relação a sua força de união com a resina composta e avaliar os tipos de falhas ocorridas. Materiais e Métodos: Foram utilizados 36 pinos da WhitepostDC (grupo GF) e Exacto Cônicos (grupo GA), divididos em: Grupos controle GF-1 e GA-1 ­ aplicação de silano de acordo com as especificações do fabricante; Grupos GF-2 e GA-2 ­ condicionamento com peróxido de hidrogênio a 10% e silanização; Grupos GF-3 e GA-3 ­ Jateamento com óxido de alumínio por 10 segundos e silanização. A adição da resina composta foi realizada em incrementos de 2 mm, com fotopolimerização de cada incremento por 40 segundos, até o preenchimento de toda extensão da matriz. Então, o conjunto pino e resina composta foi seccionado em três porções (cervical, médio e apical) (n = 18). As amostras foram submetidas à análise de resistência de união através do teste Push-Out em uma Máquina de Ensaio Universal (EMIC), e os tipos de falhas foram avaliados com aumento 30 × com um microscópio óptico. Os dados foram submetidos à análise de variância, ao teste de Tukey e ao teste de qui-quadrado com significância de 5%. Resultados: Nos grupos GA, o tratamento com silano (23,10 MPa) resultou em resistência de união estatisticamente maior que os tratamentos com peróxido (17,19 MPa) e com jateamento (16,28 MPa). No tratamento com peróxido, a resistência de união foi estatisticamente maior no terço médio (21,16 MPa) que no terço apical (12,55 MPa). A falha do tipo mista teve a maior prevalência (57,01%). Conclusão: O tratamento com silano apresentou maior resistência de união, com diferença estatística dos demais grupos na marca Angelus


Introduction: The aim of this study was to evaluate the influence of different surface treatment methods on glass-fiber posts relative to their bond strength with the composite resin and to evaluate the types of failures that occurred. Materials and Methods: Thirty-six posts from WhitepostDC (FG group) and Exacto Conics (AG group) were used, divided into: Control FG-1 and AG-1 groups ­ application of silane, according to manufacturers' specifications; FG-2 and AG-2 groups ­ conditioning with 10% hydrogen peroxide and silanization; FG-3 and AG-3 groups ­ aluminum oxide blasting for 10 seconds and silanization. The composite resin was added in 2-mm increments, each increment was photopolymerized for 40 seconds, until the entire length of the matrix was filled. Then, the assembly (fiber post and composite resin) was sectioned into three portions (cervical, middle and apical) (n = 18). Samples were submitted to the bond strength analysis by a push-out test in a Universal Testing Machine and the failure types were evaluated with a 30 × magnification with an optical microscope. Data were submitted to the analysis of variance, the Tukey test, and the chi-square test with a 5% significance level. Results: For AG groups, the treatment with silane (23.10 MPa) resulted in statistically greater bond strength than the treatments with peroxide (17.19 MPa) and blasting (16.28 MPa). It was found that the bond strength was statistically higher in the middle third (21.16 MPa) than in the apical third (12.55 MPa) for the peroxide treatment. The mixed-type failure had the highest prevalence (57.01%).


Assuntos
Teste de Materiais , Resinas Compostas , Pinos Dentários
9.
Rev. Ciênc. Plur ; 7(2): 47-60, maio 2021. ilus, tab
Artigo em Português | BBO - Odontologia, LILACS | ID: biblio-1282724

RESUMO

Introdução:As atuaisresinas Bulk-Fill apresentamcomovantagens e propriedades: menor tempo clínico, baixa contração de polimerização, maior translucidez, entre outros. Objetivo:Avaliar a topografia superficial de restaurações com diferentes tipos de resina composta antes e após submetê-las a diferentes sistemas de acabamento e polimento. Metodologia:Confecção de100 corpos de prova, sendo 50 de cada composto resinoso, apresentando cinco grupos (n=10) sorteados de forma aleatória, de acordo com o sistema de acabamento e polimento empregado. Foram utilizadas as resinas Filtek Z350 XT e a Bulk Fill Filtek One Bulk Fill e os sistemas de acabamento e polimento: Discos de Lixa Sof-Lex Pop On Kit;Discos Diamantado Espiral Sof-Lex; Ponta Enhance e Broca Carbide Multilaminada nº 0283F, que foram comparados com superfície deixada pela Tira de Poliester (Controle Negativo). Após 7 dias de armazenamento em água destilada, os corpos de provaforam submetidos aoMicroscópio Eletrônico de Varredura.Resultados:Os corpos de provada resina Bulk Fill tiveram como melhor resultado o sistema de acabamento e polimentocom broca carbidee resultado não satisfatório com discodiamantado espiral Sof-lex, enquanto a ponta Enhance e lixa Sof-lex Pop Ontiveram resultados semelhantes. Os corpos de prova da resina Filtek Z350 XT tiveram melhor aspecto visual de lisura no grupo controle negativoe pior resultado no grupo com disco diamantado espiral Sof-lex. Conclusões:Dessa forma, o sistema que apresentou melhor resultado foi a broca Carbidena resina Bulk Fill, enquanto a Filtek Z350 XT apresentou-se melhor no grupo controle. Porém, ainda são necessáriosestudos para se chegar em um protocolo de acabamento e polimento mais eficiente (AU).


Introduction:The current Bulk-Fill resins have the following advantages and properties: less clinical time, low polymerization shrinkage, greater translucency, among others.Objective:Toevaluate the topography of restorations with different types of composite resin before and after submitting them to different finishing and polishing systems.Methodology:Manufacture of 100 specimens, 50 of each resin compound, presenting five groups (n = 10) drawn at random, according to the finishing and polishing system employed. Filtek Z350 XT resins and Bulk Fill Filtek One Bulk Fill andfinishing and polishing systems were used: Sof-Lex Pop On Kit Sanding Discs; Diamond Spiral Sof-Lex Discs; Tip Enhance and Multilaminated Carbide Drill nº 0283F, which were compared with the surface left by the Polyester Strip (Negative Control). After 7 days of storage in distilled water, the specimens were submitted to a Scanning Electron Microscope.Results:The Bulk Fill resin specimens had the best result of the finishing and polishing system with carbide drill and unsatisfactory result with Sof-lex spiral diamond disc, while the Enhance tip and Sof-lex Pop On sandpaper had similar results. The Filtek Z350 XT resin specimens had a better visual aspect of smoothness in the negative control group and a worse result in the group with Sof-lex spiral diamond wheel.Conclusions:Thus, the system that showed the best result was the Carbide drill in Bulk Fill resin, while Filtek Z350 XT was better in the control group. However, studies are still needed to arrive at a more efficient finishing and polishing protocol (AU).


Introducción:Las actuales resinas Bulk-Fill tienen las siguientes ventajas y propiedades: menor tiempo clínico, baja contracción de polimerización, mayor translucidez, entre otras.Objetivo: Evaluar la topografía de restauraciones con diferentes tipos de resina compuesta antes y después de someterlas a diferentes sistemas de acabado y pulido.Metodología: Fabricación de 100 probetas, 50 de cada resina compuesta, presentando cinco grupos (n = 10) extraídos al azar, según el sistema de acabado y pulido empleado. Se utilizaron resinas Filtek Z350 XT y Bulk Fill Filtek One Bulk Fill y sistemas de acabado y pulido: Discos de lijado Sof-Lex Pop On Kit; Discos Sof-Lex en espiral de diamante; Broca Realce de Punta y Carburo Multilaminado nº 0283F, que fueron comparadas con la superficie dejada por la Tira de Poliéster (Control Negativo). Después de 7 días de almacenamiento en agua destilada, lasmuestras se sometieron a un Las muestras de resina Bulk Fill tuvieron el mejor resultado del sistema de acabado y pulido con broca de carburo y un resultado insatisfactorio con el disco de diamante en espiral Sof-lex, mientras que la punta Enhance y el papel de lija Sof-lex Pop On tuvieron resultados similares. Las muestras de resina Filtek Z350 XT tuvieron un mejor aspecto visual de suavidad en el grupo de control negativo y un peor resultado en el grupo con disco de diamante en espiral Sof-lex.Conclusiones: Así, el sistema que mejor resultado mostró fue la broca Carbide en resina Bulk Fill, mientras que Filtek Z350 XT fue mejor en el grupo control. Sin embargo, aún se necesitan estudios para llegar a un protocolo de acabado y pulido más eficiente (AU).


Assuntos
Propriedades de Superfície , Microscopia Eletrônica de Varredura/instrumentação , Resinas Compostas , Polimento Dentário/instrumentação , Técnicas In Vitro/métodos , Brasil , Polimerização
10.
Dent. press endod ; 11(1): 40-45, Jan-Apr2021. Tab, Ilus
Artigo em Inglês | LILACS | ID: biblio-1348171

RESUMO

Objetivo: Testar a hipótese nula de que a orientação das ranhuras superficiais não influencia na vida em fadiga de fios de níquel-titânio (NiTi). Material e Métodos: Segmentos de fio de NiTi (Moreli, Sorocaba/SP, Brasil) medindo 30mm e com diâmetro de 0,40mm foram utilizados. As ranhuras foram criadas em relação à direção longitudinal, em 45 e 90 graus. O fio foi analisado sob microscopia eletrônica de varredura e a rugosidade, quantificada por interferometria. O número de ciclos para a fratura (NCF) foi determinado pelo teste de flexão rotativa. Resultados: A rugosidade entre os grupos de 45 e 90 graus apresentou diferenças estatisticamente significativas (p<0,05). O grupo sem ranhuras apresentou o maior NCF (p<0,05). O grupo com ranhuras em 45 graus apresentou maior NCF, em comparação ao grupo com 90 graus (p<0,05). Conclusões: A direção das ranhuras possui influência na vida em fadiga dos fios de NiTi. O NCF aumenta com a redução do ângulo das ranhuras em relação ao longo eixo do fio, independentemente da profundidade das ranhuras (AU).


Objective: this study tested the null hypothesis that the surface grooves orientation does not influence the NiTi wire cyclic fatigue. Material and methods: Segments of NiTi wire (Moreli, Sorocaba, Brazil) measuring 30mm and with a 0.40mm of diameter were used. Grooves were created in the longitudinal direction, at 45 degrees and 90 degrees. The wire was analyzed with SEM and the roughness was quantified by interferometry. The number of cycles until fracture (NCF) was determined by the cyclic fatigue test. Results: the roughness between 45 and 90 degrees groups presented differences (p<0.05). The group without grooves presented the highest NCF (p<0.05). The group with 45 degrees grooves presented better NCF in comparison to the group with 90 degrees (p<0.05). Conclusions: the direction of the grooves influences the fatigue life. The NCF increases with the reduction of the angle of the grooves in relation to the long axis, regardless of the depth of the grooves (AU).


Assuntos
Humanos , Microscopia Eletrônica de Varredura , Ligas Dentárias , Fadiga , Interferometria
11.
Araçatuba; s.n; 2021. 137 p. ilus, graf, tab.
Tese em Inglês, Português | LILACS, BBO - Odontologia | ID: biblio-1436158

RESUMO

O objetivo deste estudo in vitro foi avaliar o efeito da aplicação de agentes antioxidantes após o clareamento dentário e previamente à cimentação de laminados cerâmicos na estabilidade cromática do conjunto restaurador, assim como nas propriedades mecânicas de nanodureza (HIT), módulo de elasticidade (Eit*), grau de conversão, resistência de união e morfologia da interface adesiva. Ademais, a neutralização de peróxido de hidrogênio e a caracterização superficial do esmalte, como ângulo de contato, energia de superfície, energia livre total de interação, microscopia eletrônica de varredura e espectroscopia de energia dispersiva do substrato submetido à ação das soluções antioxidantes e do agente clareador também foram analisados. Duzentos e quarenta e dois blocos de esmalte dentário (7x8x0,6mm) foram utilizados para o processo de cimentação e distribuídos em grupos experimentais de acordo com os métodos de procedimentos (grupo não clareado, grupo clareado com Whiteness HP Maxx 35%), tipos de antioxidantes adotados (controle; ácido ascórbico 10% e α-tocoferol 10%) e períodos de cimentação (após 24 horas e 14 dias do processo de cimentação) (n = 22). Foi utilizado o sistema adesivo Tetric N Bond Universal e o cimento resinoso Variolink Esthetic LC (Ivoclar Vivadent) como agentes cimentantes. Os dados foram submetidos a testes estatísticos de normalidade e analisados por ANOVA e teste de Tukey (α = 0,05). Os dados da morfologia da interface adesiva, obtidas pela microscopia confocal a laser, foram submetidas ao teste Kappa inter-examinadores e os dados foram submetidos aos testes Kruskal-Wallis e Dunn (α = 0,05). Os resultados mostraram que, de modo geral, a utilização da solução antioxidante α-tocoferol 10% pós-clareamento no período mediato promoveu resultados satisfatórios com relação à estabilidade cromática do conjunto restaurador, assim como para as propriedades mecânicas, grau de conversão, resistência de união e morfologia da interface adesiva comparado ao grupo clareado sem associação dos agentes antioxidantes, tanto para o período mediato, quanto para o período de 14 dias (p< 0,05). A solução de αtocoferol 10% apresentou maiores valores de neutralização do peróxido de hidrogênio e maiores valores de molhabilidade do esmalte em relação aos grupos controle e ácido ascórbico (p< 0,05). A energia de superfície e energia livre total de interação do esmalte dentário foi significativamente influenciada pelo tratamento clareador (p< 0,05). Dessa forma, conclui-se que o emprego da solução antioxidante α-tocoferol 10% promoveu resultados promissores, sugerindo que o mesmo poderia ser utilizado mediatamente após o clareamento dental na cimentação de laminados cerâmicos(AU)


The aim of this in vitro study was to evaluate the effect of antioxidant agents application after tooth bleaching and prior to luting of ceramic veneers on color stability of the restorative set, as well as on mechanical properties of nanohardness (HIT), elastic modulus (Eit*), degree of conversion, bond strength and morphology of the adhesive interface. Furthermore, the hydrogen peroxide neutralization and surface characterization of enamel, such as contact angle, surface energy, total free energy of interaction, scanning electron microscopy and energy-dispersive spectroscopy of the substrate submitted to the action of antioxidant solutions and bleaching agent were also analyzed. Two hundred forty two dental enamel blocks (7 x 8 x 0.6 mm) were used for the luting process and distributed into experimental groups according to the procedure methods (unbleached group, bleached group with Whiteness HP Maxx 35%), types of antioxidants adopted (control; 10% ascorbic acid and 10% α-tocopherol) and the luting periods (24 hours and 14 days after the luting process) (n = 22). Tetric N Bond Universal adhesive system and Variolink Esthetic LC resin cement (Ivoclar Vivadent) were used as luting agents. Data were submitted to statistical tests of normality and analyzed by ANOVA and Tukey tests (α = 0.05). The adhesive interface morphology data, obtained by confocal laser microscopy, were submitted to the interexaminer Kappa test and the data were submitted to Kruskal-Wallis and Dunn´s tests (α = 0.05). The results showed that, in general, the use of 10% α-tocopherol antioxidant solution after bleaching in mediate period promoted satisfactory results regarding the color stability of the restorative set, as well as for the mechanical properties, degree of conversion, shear bond strength and adhesive interface morphology compared to the bleached group without antioxidant agents association, both for the mediate and 14-day period (P < 0.05). The 10% αtocopherol solution showed higher hydrogen peroxide neutralization values and higher enamel wettability values compared to the control and ascorbic acid groups (P < 0.05). Surface energy and total free energy of interaction of tooth enamel were significantly influenced by the bleaching treatment (P < 0.05). Thus, it is concluded that the use of 10% αtocopherol antioxidant solution promoted promising results, suggesting that it could be used mediately after tooth bleaching on luting of ceramic laminates(AU)


Assuntos
Clareamento Dental , Cerâmica , Cimentação , Antioxidantes , Ácido Ascórbico , Espectrometria por Raios X , Propriedades de Superfície , Estresse Oxidativo , Cimentos de Resina , Tocoferóis , Cimentos Dentários , Esmalte Dentário , Resistência ao Cisalhamento , Módulo de Elasticidade , Dureza , Peróxido de Hidrogênio
12.
Araçatuba; s.n; 2021. 84 p. tab, ilus, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1413753

RESUMO

A proposição do trabalho foi avaliar o comportamento biológico e mecânico ao tecido ósseo periimplantar em implantes manufaturados em Ti-cp com superfícies usinada (CPMS) e modificada por LASER (CPLS) e implantes manufaturados em Ti6Al4V com superfícies usinada (ALLOYMS) e modificada por LASER (ALLOYLS). As superfícies foram analisadas por meio da microscopia eletrônica de varredura acoplado a espectroscopia por energia dispersiva de raios X (MEV-EDX) previamente a cirurgia experimental. Noventa e seis (2x4mm) implantes foram instalados em leitos cirúrgicos fresados nas tíbias direita e esquerda de 48 ratos Wistar machos, sendo um implante de cada material (metal) ou superfície instalado em cada tíbia. Análise biomecânica foi realizada por meio do torque de remoção dos implantes em todos os grupos nos períodos de 14, 21 e 42 dias pós-operatório e as tíbias foram seccionadas e processadas para análise histológica e imunoistoquímica. Posteriormente, foi realizada MEV-EDX dos implantes removidos por torque reverso em todos os períodos de análises. Os dados obtidos na análise biomecânica foram submetidos à análise estatística (p< 0,05). MEV-EDX antes da instalação dos implantes apresentou diferença entre as superfícies usinadas e modificadas por LASER, independente do metal do implante. O torque de remoção de ALLOYLS foi estatisticamente superior a CPLS, CPMS e ALLOYMS em 14 e 21 dias (p < 0,05), bem como CPLS foi estatisticamente superior a CPMS e ALLOYMS. Aos 42 dias CPLS e ALLOYLS apresentaram diferenças estatística quando comparados com CPMS e ALLOYMS (p< 0,05), porém não foi observada diferença entre CPLS e ALLOYLS (p = 0,07). O MEV-EDX dos implantes removidos por contra-torque evidenciou o recobrimento ósseo total das superfícies de CPLS e ALLOYLS, independe do período analisado e um aumento gradual de recobrimento ósseo nas superfícies de CPMS e ALLOYMS nos períodos de 14, 21 e 42 dias respectivamente, sendo que o CPLS aos 42 dias apresentou característica de tecido ósseo mais maturo. Na análise histológica qualitativa observa-se um tecido ósseo mais maturo, sugerindo aceleração do processo de reparo ósseo nos grupos CPLS e ALLOYLS. Para análise imunoistoquímica observou-se uma maior expressão de OPN (osteopontina) para os grupos ALLOYLS 14 e 21 dias pós-operatório, surgindo de maior ativação celular. Os implantes com modificação de superfície por ablação a LASER, independente do material manufaturado, proporcionaram importantes modificações físico-químicas na superfície, permitindo melhor embricamento mecânico com o tecido ósseo e aceleração do processo de osseointegração quando comparados com implantes com superfície usinada(AU)


This study aimed to evaluate the biological and mechanical behavior of peri-implant bone tissue in implants manufactured in cp-Ti with machined surfaces (CPMS) and modified by LASER (CPLS) and implants manufactured in Ti6Al4V with machined surfaces (ALLOYMS) and modified by LASER (ALLOYLS). The surfaces were analyzed using scanning electron microscopy coupled with X-ray dispersive energy spectroscopy (SEM-EDX) prior to experimental surgery. Ninety-six (2x4mm) implants were installed in surgical beds milled in the right and left tibias of 48 male Wistar rats, one implant of each material (metal) or surface installed in each tibia. Biomechanical analysis was performed using the implant removal torque in all groups in the periods of 14, 21 and 42 days postoperatively and the tibias were sectioned and processed for histological and immunohistochemical analysis. The data obtained in the biomechanical analysis were submitted to statistical analysis (p < 0.05). The SEM-EDX before the installation of the implants showed a difference between the surfaces machined and modified by LASER, regardless of the metal of the implant. The removal torque of ALLOYLS was statistically higher than CPLS, CPMS and ALLOYMS in 14 and 21 days (p < 0.05), as well as CPLS was statistically higher than CPMS and ALLOYMS. In 42 days CPLS and ALLOYLS showed statistical differences when compared to CPMS and ALLOYMS (p < 0.05), however no difference was observed between CPLS and ALLOYLS (p = 0.07). The SEM-EDX of the implants removed by removal torque showed the total bone coverage of the surfaces of CPLS and ALLOYLS, regardless of the analyzed period and a gradual increase in bone coverage on the surfaces of CPMS and ALLOYMS in the periods of 14, 21 and 42 days respectively, CPLS in 42 days showed a mature bone tissue. In the qualitative histological analysis, a mature bone can be observed, suggesting an acceleration of the repair process in the CPLS and ALLOYLS groups. For immunohistochemical analysis, a higher expression of OPN (osteopontin) was observed for the ALLOYLS groups in 14 and 21 days, arising from higher cellular activation. The implants with surface modification by LASER beam, regardless of the material manufactured, provided important physical-chemical modifications on the surface, allowing better mechanical resistance with bone tissue and acceleration of the osseointegration process when compared to implants with machined surfasse(AU)


Assuntos
Animais , Ratos , Implantes Dentários , Osseointegração , Lasers , Osso e Ossos , Microscopia Eletrônica de Varredura , Ratos Wistar , Implantação Dentária , Implantação Dentária Endóssea
13.
Braz. dent. sci ; 24(3): 1-8, 2021. ilus
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1282062

RESUMO

Objective: To evaluate the effect of scaling procedures using different ultrasonic tips on the surface roughness, color stability and bacterial accumulation of lithium disilicate ceramic. Material and Methods: Scaling procedure was carried out using ultrasonic scaler (Satalec, Acteon, North America) with stainless-steel tip (US), titanium tip (UT) and plastic tip (UP), on disc shaped lithium disilicate samples cemented into a cavity prepared onto the labial surface of freshly extracted bovine teeth (10 samples per group). The samples were stored in coffee solution in an incubator at 37°C for 12 days, which is equivalent to 1 year of coffee consumption. The surface roughness was measured before and after the scaling procedure using a profilometer and atomic force microscopy. The color parameters were measured before and after scaling and staining procedures using VITA Easyshade Advance 4.0 according to the CIE L*a*b* color order system. The samples were then incubated with Streptococcus mutans (S. mutans) suspension. After incubation, the plates with 30 to 300 typical colonies of S. mutans were counted in a colony counter and mean values of colony forming units were obtained (CFU/mL). Results:The titanium scaling tip showed a statistically significant higher mean values of change in surface roughness ΔRa and bacterial count than the plastic scaling tip. Color changes (ΔE) were not a statistically significant among the groups. The results showed a statistically significant positive (direct) correlation between surface roughness and color change (p = 0.012) and also between surface roughness and bacterial count (p = 0.00). Conclusion: Within the limitations of this study, titanium scaling instruments cause irreversible surface alterations of lithium disilcate ceramics which was in direct correlation to the color changes and bacterial accumulation; therefore, dentists should proceed with caution when scaling lithium disilicate surfaces. The findings of the current study may indicate the need for instruments or equipment that can remove plaque and calculus without causing surface damage (AU)


Introdução: Avaliar o efeito de procedimentos de raspagem com diferentes pontas de ultrassom na rugosidade superficial, estabilidade de cor e acúmulo bacteriano em cerâmica de dissilicato de lítio. Material e Métodos: O procedimento de raspagem foi realizado usando um aparelho de ultrassom (Satalec, Acteon, América do Norte) com ponta de aço inoxidável (US), ponta de titânio (UT) e ponta de plástico (UP), em amostras de dissilicato de lítio em forma de disco cimentadas em uma cavidade preparada na superfície vestibular de dentes bovinos recém-extraídos (10 amostras por grupo). As amostras foram armazenadas em solução de café em incubadora a 37 ° C por 12 dias, o que equivale a 1 ano de consumo de café. A rugosidade da superfície foi medida antes e após o procedimento de raspagem usando um perfilômetro e um microscópio de força atômica. Os parâmetros de cor foram medidos antes e depois dos procedimentos de raspagem e armazenagem no café usando VITA Easyshade Advance 4.0 de acordo com o sistema de ordem de cores CIE L*a*b*. As amostras foram incubadas com suspensão de Streptococcus mutans (S. mutans). Após a incubação, as placas com 30 a 300 colônias típicas de S. mutans foram contadas em contador de colônias e obtidos os valores médios das unidades formadoras de colônias (UFC / mL). Resultados: A ponta de titânio mostrou valores estatisticamente maiores de mudança na rugosidade da superfície ΔRa e contagem de bactérias do que a ponta de raspagem de plástico. A mudança de cor (ΔE) não foi estatisticamente significativa entre os grupos. Os resultados mostraram uma correlação positiva (direta) estatisticamente significativa entre rugosidade superficial e alteração de cor (p = 0,012) e também entre rugosidade superficial e contagem bacteriana (p = 0,00). Conclusão: Dentro das limitações deste estudo, os instrumentos de raspagem de titânio causam alterações irreversíveis na superfície das cerâmicas de dissilicato de lítio que estão em correlação direta com as mudanças de cor e o acúmulo de bactérias. Portanto, os dentistas devem proceder com cautela ao realizar raspagem em superfícies de dissilicato de lítio. Os resultados deste estudo podem indicar a necessidade de instrumentos ou equipamentos que possam remover a placa e cálculo sem causar danos à superfície. (AU)


Assuntos
Propriedades de Superfície , Ultrassom , Aderência Bacteriana , Raspagem Dentária , Cor
14.
Rev. Fac. Odontol. Porto Alegre ; 61(2): 50-63, jul-dez. 2020.
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1281698

RESUMO

Objetivo: Este ensaio clínico randomizado avaliou o comportamento de restaurações com resina composta bulk-fill flow em dentes posteriores após três anos do tratamento restaurador. Métodos: Dezessete pacientes (12 mulheres, 5 homens, idade 23-59) foram selecionados para ter pelo menos duas restaurações de amálgama ou de resina composta substituídas, ou receber tratamento restaurador para lesão cariosa. As cavidades foram aleatoriamente alocadas para receberem o compósito bulk-fill flow Suferil SDR Flow, oclusamente coberto por uma resina composta convencional nano-híbrida Esthet-X HD (técnica bulk and body), ou serem preenchidas exclusivamente com Esthet-X HD, inseridas em incrementos de 2mm cada técnica incremental). Um adesivo convencional de dois passos foi aplicado em todas as cavidades. Trinta e quatro restaurações Classes I ou II foram realizados em dentes posteriores (n=17) no início do estudo (baseline). Após 03 anos, os critérios do USPHS modificado e FDI foram utilizados para avaliar as restaurações. Os dados foram submetidos à análise estatística Mann-Whitney (p<0,05). Resultados: No acompanhamento de 3 anos, vinte e quatro restaurações (17 Classes I e 7 Classes II) foram avaliadas. Não foram detectadas diferenças entre as técnicas restauradoras (p>0,05). Não houve falha em nenhuma restauração ao longo do tempo. Conclusão: Após 03 anos de serviço clínico, todas restaurações utilizando um compósito bulk-fill flow em dentes posteriores demonstraram uma performance satisfatória. Significância Clínica: A qualidade geral das restaurações em dentes posteriores realizadas com a técnica bulk and body foi similar ao das restaurações incrementais utilizando um compósito nano-híbrido. (AU)


Objective: This randomized clinical trial evaluated the behavior of restorations with flowable bulk-fill resin composite in posterior teeth three years after the restorative treatment. Methods: Seventeen patients (12 women, 5 men, age 23-59) were selected to have at least two failing amalgam or resin restorations replaced and/or to have a carious lesion restored. The cavities were randomly allocated to receive either the flowable bulk-fill composite Surefil SDR Flow occlusally covered with the conventional nano-hybrid composite Esthet-X HD (bulk and body technique) or filled exclusively with Esthet-X HD placed in 2 mm increments (incremental technique). A two-step etch-and-rinse adhesive was applied in all cavities. Thirty-four Class I or II restorations were performed in posterior teeth (n=17) during baseline. After 03 years, modified USPHS and FDI criteria were used to evaluate the restorations. Data were subjected to Mann-Whitney statistical analysis (p<0.05). Results: At the 3-year follow-up, twenty-four restorations (17 Class I and 7 Class II) were evaluated. No diff erences were detected between the bulk and body and the incremental restorations (p>0.05). No restoration failures were observed over time. Conclusion: After 03 years of clinical service, all restorations using a flowable bulk-fill composite in posterior teeth showed an acceptable performance. Clinical Significance: The overall quality of posterior restorations made with the bulk and body technique was similar to that of restorations made with a nano-hybrid composite incrementally placed. (AU)


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Adulto Jovem , Resinas Compostas , Restauração Dentária Permanente/métodos , Dente Pré-Molar , Método Duplo-Cego , Seguimentos , Estatísticas não Paramétricas , Dente Molar
15.
Acta odontol. latinoam ; 33(2): 59-68, Sept. 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1130735

RESUMO

ABSTRACT The aim of this in vitro study was to evaluate the effect of bleaching protocols on the surface roughness (Ra), color change and surface micromorphology of a low-viscosity bulk-fill composite (Filtek Bulk Fill Flow, 3M ESPE), a highviscosity bulk-fill composite (Filtek Bulk Fill, 3M ESPE) and a conventional nanoparticulate composite resin (control) (Filtek Z350 XT, 3M ESPE). Forty samples of each composite (disks 5 mm in diameter and 2 mm thick) were randomly divided into four groups (n=10), according to bleaching protocol: a) 10% carbamide peroxide gel (Opalescence, Ultradent Products) (2 h/ day, for 14 days); b) 40% hydrogen peroxide gel (Opalescence Boost, Ultradent Products) (three bleaching sessions, once a week, 45 min/session); c) whitening rinse (Listerine Whitening Extreme, Johnson & Johnson) (2 min/day, for 14 days); and d) distilled water (control). The samples were submitted to triplicate readings (Ra and color [CIELAB parameters]) before and after contact with bleaching protocols. Micromorphology was analyzed in a scanning electron microscope (SEM). Ra and color parameters (ΔL, Δa, Δb and ΔE) were analyzed by generalized linear models (α=0.05). The Ra of the high-viscosity bulk-fill was significantly higher than that of the other composites (p<0.05). Ra increased significantly (p<0.05) and surface became more irregular (SEM analysis) in all the composite resins, regardless of the bleaching protocol (p<0.05). The high-viscosity bulk-fill composite resin group had significantly lower ΔE (p<0.05) than the nanoparticulate composite resin group immersed in distilled water. It was concluded that the characteristics of each resin significantly influenced the Ra more than the bleaching protocol. The high-viscosity bulk-fill resin presented minor color change.


RESUMO Este estudo in vitro teve objetivo de avaliar o efeito de protocolos clareadores sobre a rugosidade de superfície (Ra), alteração de cor e micromorfologia de resina bulk-fill de baixa viscosidade (Filtek Bulk Fill Flow, 3M ESPE), alta viscosidade (Filtek Bulk Fill, 3M ESPE) e de uma resina composta nanoparticulada (controle) (Filtek Z350 XT, 3M ESPE). Quarenta amostras de cada resin composta (discos de 5 mm de diâmetro e 2 mm de espessura) foram aleatoriamente divididas em quatro grupos , de acordo com protocolo clareador (n=10): a) Gel de peróxido de carbamida (Opalescence, Ultradent Products) (2 horas/dia, por 14 dias); b) Gel de peróxido de hidrogênio (Opalescence Boost, Ultradent Products) (3 sessões de clareamento, uma por semana, 45 min/sessão); enxaguatório clareador (Listerine Whitening Extreme, Johnson & Johnson) (2 min/dia, por 14 dias); d) água destilada (controle). As amostras foram submetidas a leituras, em triplicata (Ra e cor (parâmetros CIELab) antes e depois do contato com os protocolos clareadores. A micromorfologia de superfície foi conduzida em microscópio eletrônico de varredura (MEV). Ra e parâmetros de cor (ΔL, Δa, Δb e ΔE) foram analisados por modelos lineares generalizados (α=0.05). A Ra da resina bulk-fill de alta viscosidade foi significantemente superior do que para os outros compósitos (pp<0.05). A Ra aumentou significantemente (p<0.05) e a superfície ficou mais irregular (MEV) para todos os compósitos, independente do protocolo clareador (pp<0,05). A resina bulk-fill de alta viscosidade obteve menor ΔE (pp<0.05) do que a resina composta nanoparticulada, imersa em água destilada. Pode-se concluir que as características de cada resina composta influenciaram de forma mais significativa a Ra do que o protocolo clareador. A resina bulk fill de alta viscosidade apresentou menor alteração de cor.


Assuntos
Humanos , Clareamento Dental/métodos , Descoloração de Dente/tratamento farmacológico , Viscosidade/efeitos dos fármacos , Resinas Compostas/química , Clareadores Dentários/química , Peróxido de Hidrogênio/química , Teste de Materiais , Cor
16.
Rev. Fac. Odontol. Porto Alegre ; 61(1): 46-58, jan-jun. 2020.
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1417644

RESUMO

Objetivo: O flúor acidulado é utilizado no controle da doença cárie, mas seus efeitos na superfície de resinas compostas são controversos. O objetivo do estudo é avaliar a rugosidade superficial de uma resina composta após a aplicação tópica de flúor in vitro. Métodos: Espécimes de resina Vittra (FGM) foram preparados (8mmx1mm) e polidos. Após avaliação do pH de produtos fluoretados, o de maior e menor pH foram selecionados para os ex-perimentos. Foram testados três grupos experimentais (n = 15): grupo 1 ­ flúor gel acidulado a 1,23% (Nova DFL) (menor pH:4,48±0,32), grupo 2 ­ flúor gel neutro a 2% (Nova DFL) (maior pH:7,03±0,40), grupo 3 ­ sem exposi-ção ao flúor (controle negativo). O experimento simulou o protocolo padrão clínico de aplicação de flúor (uma aplicação por semana, durante um minuto, por quatro semanas). A rugosidade superficial foi mensurada antes e após o tratamento através de microscopia confocal e a característica superficial avaliada por imagens reconstru-ídas. Foi realizado teste ANOVA (post-hoc de Bonferroni) para comparar médias da rugosidade superficial entre grupos. Resultados: O grupo exposto ao flúor gel acidu-lado apresentou os maiores valores de rugosidade (Ra: 0,29±0,08), sendo maior que o grupo exposto ao gel neutro (Ra: 0,21±0,08) e controle (Ra: 0,23±0,05) (p < 0,05), que não apresentaram diferença estatística entre si. Conclusão: O grupo exposto ao flúor acidulado mostrou rugosidade superficial maior que o controle, porém essa diferença pode ser clinicamente irrelevante. Novos estudos são necessários para avaliar se tal alteração aumenta a adesão bacteriana e se a resina deve ser polida após aplicações tópicas de flúor.


Aim: Acidulated fluoride is widely used to control dental caries, however, its effects on composites surfaces are controversial. This study aimed to evaluate the surface roughness of a composite af-ter a fluoride topical application in vitro. Methods: Vittra (FGM) composite specimens were made (8mmx1mm) and polished. After pH evaluation of fluoridated products, the ones with the highest and lowest pH were selected for the experiments. Three experimental groups (n = 15) were tested: group 1 - 1.23% acidulated fluoride gel (Nova DFL) (pH: 4.48±0.32), group 2 - 2% neutral fluoride gel (Nova DFL) (pH: 7.03±0.40), group 3 - no fluoride exposure (negative control). The experiment simulated the standard clinical fluoride application protocol (one application of one minute per week,in four weeks). Surface roughness was measured before and after treatment by confocal microscopy and the surface characteristic evaluated by reconstructed images. ANOVA (Bonferroni post-hoc) test was performed to compare means of surface roughness between groups. Results: The group exposed to acidulated fluoride gel presented the highest values of roughness (Ra: 0.29±0.08), being larger than the group exposed to neutral fluoride gel (Ra: 0.21±0.08) and control (Ra: 0.23±0.05) (p < 0.05), which showed no statistical difference between them. Conclusion: It was concluded that the group exposed to acidula-ted fluoride showed greater surface roughness than the control group, but this difference appears to be clinically irrelevant. Further studies are needed to assess whether this change increases bacterial adhesion and whether the resin should be polished after topical fluoride applications.


Assuntos
Propriedades de Superfície , Resinas Compostas , Fluoretos , Flúor , Fluoreto de Fosfato Acidulado
17.
Araçatuba; s.n; 2020. 61 p. ilus, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1434476

RESUMO

Objetivo: Avaliar o processo de reparo ao redor de implantes com as superfícies usinada (SU), superfície disponível comercialmente modificada por jateamento de óxido de alumínio seguido do condicionamento ácido (SJA), modificada por feixe de LASER (SL) e modificada por feixe de LASER com posterior recobrimento de hidroxiapatita através do método biomimético sem tratamento térmico (SLH). Material e Métodos: As superfícies foram analisadas através de microscopia eletrônica de varredura acoplado a espectroscopia por energia dispersiva de raios X (MEV-EDX) previamente a cirurgia. Vinte coelhos receberam randomicamente 40 implantes em suas tíbias direita e esquerda, sendo um implante de cada superfície em cada tíbia. No procedimento cirúrgicos e nos períodos de 2 e 4 semanas foi mensurado o coeficiente de estabilidade do implante através da análise de frequência por ressonância (FR), seguida da remoção por contra-torque dos implantes nos períodos de análise. Os dados obtidos foram submetidos à análise de variância e ao teste t de Tukey (FR) e Kruskal-Wallis (análise biomecânica). Resultados: MEV e EDX mostraram diferenças na topografia das superfícies. Não houve diferença estatisticamente significante entre os grupos na análise de frequência por ressonância. Foi observada diferença estatisticamente significante no torque de remoção entre o grupo SL e SLH quando comparados ao grupo SU no período de 2 semanas. Já no período de 4 semanas, foi observada diferença estatística entre as 2 superfícies experimentais SL e SLH quando comparadas as superfícies SU e SJA. Na análise histológica os grupos SL e SLH apresentaram remodelação óssea no período de 2 semanas e osso maduro no período de 4 semanas, diferente de SU e SJA que apresentaram um atraso no reparo perante as superfícies experimentais. Conclusão: Os implantes com superfície SL e SLH apresentaram propriedades topográficas, e biomecânicas superiores às das superfícies SU e SJA(AU)


Purpose: To evaluate the repair process around implants with the machined surfaces (SU), commercially available surface modified by aluminum oxide blasting followed by acid etching (SJA), modified by LASER beam (SL) and modified by LASER beam with subsequent coating of hydroxyapatite using the biomimetic method without thermal treatment (SLH). Material and Methods: The surfaces were analyzed using scanning electron microscopy coupled with dispersive energy X-ray spectroscopy (SEM-EDX) prior to surgery. Twenty rabbits randomly received 40 implants in their right and left tibiae, with one implant on each surface in each tibia. In the surgical procedure and in the periods of 2 and 4 weeks, the implant stability coefficient was measured through the resonance frequency (ISQ), followed by the removal by counter-torque of the implants in the analysis periods. The data obtained were subjected to analysis of variance and Tukey's t test (ISQ) and Kruskal-Wallis (biomechanical analysis). Results: SEM and EDX showed differences in surface topography. There was no statistically significant difference between the groups in the resonance frequency. There was a statistically significant difference in the removal torque between the SL and SLH group when compared to the SU group in the period of 2 weeks. In the 4-week period, a statistical difference was observed between the 2 experimental surfaces SL and SLH when comparing the SU and SJA surfaces. In the histological analysis, the SL and SLH groups presented bone remodeling in the period of 2 weeks and mature bone in the period of 4 weeks, unlike SU and SJA which presented a delay in repair before the experimental surfaces. Conclusion: Implants with SL and SLH surfaces showed topographic and biomechanical properties superior to those of SU and SJA surfaces(AU)


Assuntos
Animais , Coelhos , Propriedades de Superfície , Implantes Dentários , Osseointegração , Durapatita , Lasers , Coelhos , Osso e Ossos , Microscopia Eletrônica de Varredura , Análise de Variância , Remodelação Óssea , Torque , Óxido de Alumínio
18.
Rev. Ciênc. Méd. Biol. (Impr.) ; 18(3): 355-360, dez 20, 2019. ilus, tab, fig
Artigo em Português | LILACS | ID: biblio-1359164

RESUMO

Introdução: uma adequada polimerização da resina composta proporciona um bom desempenho clínico e propriedades físicas satisfatórias na restauração. A conversão de monômeros em polímeros depende não só da luz visível emitida pelo fotopolimerizador e do sistema fotoiniciador presente na resina composta, como também da quantidade de energia que alcança a resina composta e que está na dependência de como essa luz é aplicada sobre a resina. Objetivo: verificar a influência do posicionamento da ponta de um fotopolimerizador de amplo espectro sobre a rugosidade de duas resinas compostas. Metodologia: previamente à confecção dos corpos de prova, foi realizada a randomização de quatro grupos experimentais (n=10) para locação dos corpos de prova, da resina Vittra APS (FGM) em duas apresentações (Vittra APS Esmalte-bleach e a Vittra APS Dentina A0) e duas variações do posicionamento da ponta do fotopolimerizador (0º e 20º). Foram confeccionados quarenta corpos de prova cilíndricos em resina composta, na dimensão 6 x 1,5 mm. Valores da Ra foram registrados usando-se um rugosímetro e analisados estatisticamente (Shapiro-Wilk/ ANOVA). A rugosidade superficial (Ra) de topo de cada corpo de prova foi individualmente avaliada, sendo realizadas três leituras por superfície em posições diferentes. Resultados: não foi verificada significância estatística da interação entre os fatores, nem foram notadas diferenças estatisticamente significativas entre os fatores isolados. Dentre os posicionamentos analisados, constatou-se que o fotopolimerizador a 20º não alterou a rugosidade das resinas utilizadas. Conclusão: a variação da angulação da ponta do fotopolimerizador em 20o não alterou a rugosidade superficial das resinas testadas.


Introduction: proper polymerization of the composite resin provides good clinical performance and satisfactory physical properties of the restoration. The conversion of monomers to polymers depends not only on the visible light emitted by the curing light and the photoinitiating system present in the composite resin, but also on the amount of energy that the composite resin reaches and is dependent on how that light is applied to the resin. Objective: to verify the influence of the tip positioning of a broad spectrum curing light on the roughness of two composite resins. Metodology: prior to the preparation of the specimens, four experimental groups (n = 10) were randomized to locate the specimens, Vittra APS resin (FGM) in two presentations (Vittra APS Enamel-bleach and Vittra APS Dentin A0) and two variations of the curing tip positioning (0º and 20º). Forty 6 x 1.5 mm composite resin cylindrical specimens were made. Ra values were recorded using a roughness meter and statistically analyzed (Shapiro-Wilk/ANOVA). The top surface roughness (Ra) of each specimen was individually evaluated and three surface readings were taken at different positions. Results: no statistical significance of the interaction between the factors was verified, nor were statistically significant differences observed between the isolated factors. Among the positions analyzed, it was found that the curing light at 20º did not change the roughness of the resins used. Conclusion: variation of the curing angle of the curing light tip at 20o did not change the surface roughness of the resins tested.


Assuntos
Humanos , Propriedades de Superfície , Saúde Bucal , Resinas Compostas , Restauração Dentária Permanente , Polimerização
19.
Rev. odontol. Univ. Cid. São Paulo (Online) ; 31(3): [61,70], set.-dez. 2019. tab
Artigo em Português | LILACS | ID: biblio-1102951

RESUMO

A evolução dos materiais e técnicas restauradoras culminou com o advento do fenômeno da osseointegração. A reabilitação oral, inicialmente de pacientes desdentados, posteriormente estendida aos casos estéticos unitários, tornou-se possível pelas múltiplas opções disponíveis. A produção em larga escala dos implantes modificou a forma, o tamanho, o diâmetro, a angulação e a textura das fixações. Busca-se uma melhor confiabilidade e menor dispêndio de tempo, acelerando-se e orientando-se a fisiologia para o uso da técnica da carga imediata. A exodontia seguida da colocação da prótese, mesmo que provisória, trouxe maior satisfação para os pacientes num mundo agitado em que as transformações se processam na velocidade dos computadores. Particularmente, a corrida comercial busca inovações técnicas que potencializem as fixações. Nesse contexto, a alteração superficial dos implantes procura orientar as células precursoras do osso a interagirem na interface osso/implante. A neoformação óssea ao redor dos implantes é responsável pela longevidade da reabilitação. Assim, a proposta foi a de verificar quais tratamentos de superfície dos implantes favorecem a osseointegração. O método utilizado foi uma revisão sistemática sobre artigos científicos em revistas e periódicos indexados e de fácil aquisição nas bases de dados PubMed, MEDLINE, Lilacs, BBO, SciELO e Google Acadêmico nos últimos 10 anos, acrescidos de referências clássicas e estudos considerados relevantes para essa publicação. O objetivo deste trabalho foi fazer uma revisão sistemática sobre os diferentes tratamentos de superfície dos implantes, ilustrando as reais possibilidades de aumento do contato osso/ implante com variadas texturas.


The evolution of materials and restorative techniques culminated with the advent of the osseointegration phenomenon. Oral rehabilitation, initially of edentulous patients, later extended to the unitary aesthetic cases, was made possible by the multiple options available. The large-scale production of the implants modified the shape, size, diameter, angulation and texture of the fixtures. It is sought a better reliability and less expenditure of time, accelerating and orienting the physiology for the use of the technique of immediate loading. The exodontia followed by the prosthesis placement, even if provisional, brought greater satisfaction to the patients in a troubled world in which the transformations are processed in the speed of the computers. In particular, the commercial race looks for technical innovations that potentiate the fixtures. In this context, the superficial alteration of the implants seeks to guide the precursor cells of the bone to interact at the bone/implant interface. The bone neoformation around the implants is responsible for the longevity of the rehabilitation. Thus, the proposal was to verify which implant surface treatments favor osseointegration. The method used was a systematic review of scientific articles in indexed and easily retrieved journals and magazines in PubMed, MEDLINE, Lilacs, BBO, SciELO and Google Scholar databases in the last 10 years, together with classic references and studies considered relevant to this publication. The aim of this work was to systematically review the different surface treatments of implants, illustrating the real possibilities of increasing bone/implant contact with varied textures.


Assuntos
Humanos , Masculino , Feminino , Propriedades de Superfície , Implantes Dentários , Prótese Ancorada no Osso
20.
J. health sci. (Londrina) ; 21(1)30/04/2019.
Artigo em Inglês | LILACS | ID: biblio-995924

RESUMO

The aim of this study was to evaluate the surface roughness of a silorane and methacrylate-based composite resins subjected to different finishing/polishing techniques. Twelve disk specimens were prepared from each composite resin: P90®, Z350® and Charisma, divided into 12 groups according to the finishing/polishing technique: no finishing/polishing (control); finishing with 1112 FF diamond burs; finishing with 1112 FF diamond burs associated to Enhance/Pogo; finishing with 1112 FF diamond burs associated to Enhance/Pogo/Polishing/Poli I and II pastes/Fotogloss. After initial readouts of surface roughness, the specimens were subjected to mechanical cycling (1.200.000 cycles) and immediately subjected to final roughness readouts. Surface roughness means was statistically analyzed by ANOVA and Tukey-Kramer test (α=0.05). SEM images were realized after finishing/polishing and after mechanical cycling. The P90 composite showed surface roughness values similar to other investigated composites. However, significant difference was observed in finishing/polishing techniques. The diamond burs group showed the highest surface roughness differing from the other composite resins (α < 0.05). Enance/Pogo showed the lowest results, which presented no difference compared to the polishing paste group (α > 0.05). The low-shrink posterior restorative showed similar surface roughness when compared to dimethacrylate composite resins and suitable to posterior restorations. (AU).


O objetivo deste estudo foi avaliar a rugosidade superficial de resinas compostas à base silorano e metacrilato submetidas a diferentes técnicas de acabamento/polimento. Foram preparadas 12 amostras de disco de cada resina composta: P90®, Z350® e Carisma, divididas em 12 grupos de acordo com a técnica de acabamento / polimento: sem acabamento / polimento (controle); acabamento com ponta diamantada 1112 FF; acabamento com ponta diamantada 1112 FF associada a Enhance / Pogo; acabamento com ponta diamantada 1112 FF associada a Enhance / Pogo / Polishing / Pastas Poli I e II / Fotogloss. Após as leituras iniciais da rugosidade da superfície, os espécimes foram submetidos a ciclos mecânicos (1.200.000 ciclos) e submetidos imediatamente a leituras de rugosidade final. As medias de rugosidade superfícial foram analisadas estatisticamente por ANOVA e teste de Tukey-Kramer (α = 0,05). As imagens de MEV foram realizadas após o acabamento / polimento e após a ciclagem mecânica. O compósito P90 mostrou valores de rugosidade superficial semelhantes a outros compósitos investigados. Tough, mostrou diferença significativa nas técnicas de acabamento / polimento. O grupo de pontas damantadas apresentou maior rugosidade superficial que diferiu das outras resinas compostas (α <0,05). Enance / Pogo mostrou os menores resultados, que não apresentaram diferença em relação ao grupo de pasta de polimento (α> 0,05). O material restaurador posterior de baixa contração apresentou rugosidade superficial semelhante quando comparado as resinas compostas de dimetacrilato e são restaurações adequadas para região posterior. (AU).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...